| Name of parameter | Unit of measurement | Value |
| Three-phase input supply voltage (Uin), with earthed neutral | V | 380 +10/-15 % |
| Input voltage frequency | Hz | 50 ± 2 % |
| Network connection periodicity | times | Once per minute or less |
| Three-phase rated output DC voltage (Uin) | V | 380 ± 2 %, but no more than Uin |
| Output voltage rated frequency (Frat) | Hz | 50 ± 1% |
| Controlled motors rated power (Рrat) | kW | from 60 up to 630 |
| Current overload | - | 1.5 Irat – 1 min per 10 min |
| Range of output voltage regulation | V | 0 – Uin |
| Range of output frequency regulation | Hz | 0.5 – 60 |
| Efficiency coefficient, minimum | - | 0.95 |
| Nonlinear network current distortions coefficient, max. | % | 5 |
| Level protection acc. to IEC 60529 (upon request) | - | IP 21, IP 43, IP 54 |
| Lifetime, minimum | years | 15 |
| Mean recovery time, max. | min | 40 |
| Interference resistance | - | meets all standards requirements |
| Overall dimensions of SHIN and VTM at traction power of 110 kW (WхHхD) | - | 1800×2200×600; 800×2000×600 |